5120 Series High Flow Mixing Valve
Performance Data
CV: 4.1
Max. Flow: 27.2 GPM*
Min. Flow: 2.5 GPM
Hot Supply Temp.: 120-180˚F (49-82˚C)
Cold Supply Temp.: 39-80°F (5-27°C)
Max. Inlet Pressure: 230 psi (15.85 Bar)
Max. Variation in Supply Pressure: 20%
Min. Temp. Differential Between Hot Supply and Mixed: 27°F (15˚C)
Outlet Temp. Range: 85-175 F (29-80˚C)
Factory set to: 115-120˚F (41-45˚C)
Accuracy of Outlet Temp.: ± 3˚F
Connection Sizes: 1″ and 1¼” Sweat
*NOTE: Flow should never exceed standards for pipe size.
Features
- ≤ .25% lead
- Delivers Stable Mixed Water Temperature
- Tamper-Resistant Temperature Adjustment
- Low Headloss
- Outlet Temperature Strip
Applications
- Domestic Water Distribution
- Potable Water