00 Series Variable Speed Circulators
Performance Data
Max. Fluid Temp.: 40F (4°C)
Max. Fluid Temp.: 230F (110°C)
Max. Working Pressure: 125 PSI (006-008), 150 PSI (009-0014)
Flow Range: 0-52 GPM
Head Range: 0′-35′
HP: 1/40 -1/8
Sizes (in): ¾” Sweat, ¾”, 1″, ¼”, 1 ½”, 2″, Flanged
Variable Speed Solar Control
Flow Range: 0-31 GPM
Head Range (ft): 0-31′
Min. Fluid Temp.: 40°F (4°C)
Max. Fluid Temp.: 230°F (110°C)
Max. Operating Pressure: 125 PSI
Connection Sizes: ½”, ¾” Sweat, ¾”, 1″, 1 ¼”, 1 ½” Flanged
Variable Speed Setpoint
Flow Range: 0-52 GPM
Head Range (ft): 0-35′
HP: 1/40 – 1/6
Min. Fluid Temp.: 40°F (4°C)
Max. Fluid Temp.: 230°F (110°C)
Max. Operating Pressure: 125 PSI
Connection Sizes (in): ¾”, 1″, 1 ¼”, 1 ½” Flanged, ¾” Bronze Sweat or ¾” NPT Stainless Steel
Variable Speed Outdoor Reset
Flow Range: 0-52 GPM
Head Range (ft): 0-35″
HP: 1/40 – 1/6
Min. Fluid Temp.: 40°F (4°C)
Max. Fluid Temp.: 230°F (110°C)
Max. Working Pressure: 125 PSI, 150 PSI
Connection Sizes: ¾”, 1″, 1 ¼”, 1 ½” Flanged, ¾” Bronze Sweat, ¾” NPT Stainless Steel
Variable Speed Delta-T
Flow Range: 0-52 GPM
Head Range (ft): 0-35′
HP: 1/40 – 1/6
Min. Fluid Temp.: 40°F (4°C)
Max. Fluid Temp.: 230°F (110°C)
Max. Operating Pressure: 125 PSI
Connection Sizes (in): ¾”, 1″, 1 ¼”, 1 ½” Flanged, ¾” Bronze Sweat or ¾” NPT Stainless Steel
00-VV Features
- 4 Signal Voltage Ranges (0-10 V(dc), 0-20 mA, 2-10V(dc), or 4-20 mA)
- Internal LED’s
- Manual Operation Switch
- Linear or Logarithmic Output
- Pump Exercise (10 Seconds After 3 Days of No Operation)
- Optional Integral Flow Check (IFC®)
- Cast Iron, Bronze or Stainless Steel Construction
00-VT Features
- All-in-One Pump and Variable Speed Solar Control
- User Definable Line Voltage Output
- Supports Drain Back Applications
- Freeze Protection for Open Systems
- Holiday Function, Minimizes Collector Stagnation
- Factory Installed Line Cord
- Adjustable Storage Tank Maximum Setting
00-VS Features
- Adjustable Setpoint (30° – 210°F)
- Adjustable Temperature Difference (DT) (5° – 50°F)
- Boiler Protection (135°F)
- Boiler Protection as a Limit Control (75° – 165°F)
- LED Status Panel
- Direct or Reverse Acting
- Pump Exercise (10 Seconds After 3 Days of No Operation)
00-VR Features
- Available in sizes 006 – 0014
- All-in-One Pump/Control
- Sensors Included
- Easy to Wire
- UL Approved
- Snap-in PC Board
- Fuse Protected
- Plug-in Low-Voltage Terminal
- Optional Integral Flow Check (IFC®)
- Adjustable Heating Curve (0.2 – 2.2)
- Selectable Max. Supply Temp. (110°F, 130°F, 150°F or Off)
- Selectable Min. Boiler Return Temp. (85°F or Off, Default to Heating Curve)
- System and/or Boiler Pump Contact (Line Voltage 5 amp or Off)
- LED Status Panel
- Pump Exercise
- Post Purge
- Fail Safe Mode
- 2-Second Start Delay to Prevent Short Cycling
00-VDT Features
- Available in sizes 008 – 0013
- All-in-One Pump/Control
- Sensors Included
- Easy to Install
- UL Approved
- Snap-in PC Board
- Fuse Protected
- Plug-in Low-Voltage Terminal
- Optional Integral Flow Check (IFC®)
Applications
- Hot Water Heating Systems
- Closed Cooling Circuits
- Air Conditioning Systems
- Hydronic Heating & Cooling
- Hydro-Air Fan Coils